Related Topics: | ||
The simulation Quick Calculation Pad (QCP) provides you with a quick and accurate way of gaining access to some of the most frequently requested reliability results for simulation diagrams and phase diagrams. You can access the simulation QCP by choosing Simulation > Simulation > Simulation QCP or by clicking its icon on the Simulation page of the diagram control panel.
The simulation QCP extracts the parameters and other information from the active RBD, fault tree or phase diagram and returns results based on the diagram and, when applicable, your inputs.
To use the QCP, do the following:
Choose a metric in the Calculate area.
If applicable, use the Units drop-down list to specify the units for time values that are entered as inputs and/or displayed as results. The units in the QCP can be different from the units that were used for the diagram. For example, you could enter the age of the block in hours but then calculate the point reliability for 1 year of operation — the application will convert the times automatically based on the conversion factors specified for the database.
Make any required inputs in the Input area.
Click Calculate. The calculated value(s) will always be displayed in the results area at the top of the window, and clicking the Report button displays a summary of the current calculation input/output in the Results window. You can also use the Options drop-down list to configure other settings, including:
Precision sets the number of decimal places displayed in the results.
Scientific Notation sets the point at which numbers will be converted to normalized scientific notation. For example, setting this to 3 means that all numbers with a value of 1,000 or more will be converted to normalized scientific notation (e.g., 1.0E+3).
Set Display Font allows to change the font style and size that is used to display the calculated value(s) in the results.
Select Captions (indicated by a green light on the button) if you want notations to be displayed in the results area along with the values. For example, if you have selected to calculate the point availability for a specific point in time, the first picture shows the display with captions and the second picture shows without.
Select Show Calculation Log (indicated by a green light on the button) if you want to display a log on the right side of the window that records some or all of the calculations performed during this QCP session.
If Auto Print Results is selected under Options, all results will be automatically printed to the log each time you perform a calculation.
Otherwise, you can choose which results to add to the log by using the Print button at the bottom of the log display.
Under the log display, you can also click Feed to "advance the tape" or Clear to delete all data from the current log. If you click inside the log, you can copy some or all of the text to the Clipboard.
Select Non-Modal QCP to lock the QCP in a top window position so it can remain open while you have access to all diagrams. The calculations performed in the QCP will be based on the currently active diagram. Note that if the currently active diagram is an analytical diagram, the QCP will change to show the calculations available for analytical diagrams. If this option is not selected, you will need to close the QCP to access any diagram. This setting can also be changed using the While QCP is open, have access to all folios option on the Other page of the Application Setup.
QCP Calculations
The following simulation calculations are available in the QCP:
Probability
Time
Life
© 1992-2013. ReliaSoft Corporation. ALL RIGHTS RESERVED.