Related Topics: | ||
The Analysis Settings page of the control panel for phase diagrams contains the following options:
Analysis Settings
Select Report subdiagram results to provide calculated results for subdiagram blocks in the Simulation Results Explorer. If this option is not selected, subdiagram blocks will not appear in the results.
Use system downtime threshold allows you to specify a minimum amount of time that the system must be down in order for it to count toward critical downtime metrics.
Select Run throughput simulation to perform the throughput simulation, which allows you to perform analyses on the number of units that can be processed by the system in the diagram during the simulation time. If you select to run a throughput simulation, you can select Report throughput point results to include throughput results in the System Point Results worksheet, which provides results at specified points in time. If this option is not selected, only the throughput results for the system at the simulation end time will be reported.
Report Settings
Report folio model allows you to specify the results model that will be used when the diagram is used as the default data source for an analysis workbook or a Word report. You can choose to use either the simulation results or the fitted model.
Max RDA data allows you to specify the maximum number of events that can be shown in the RDA Data worksheet in the Simulation Results Explorer. The contents of the RDA Data worksheet can be transferred to a parametric RDA folio in Weibull++ for further analysis.