Related Topics: | ||
Description: Allows you to manually build a table that shows the first times-to-failure for a given mode type. This applies only to data sets analyzed with the Crow Extended or Crow Extended - Continuous Evaluation models.
Field Format: [FTTFUNIQUE(Source Number)(Row;Column;Mode_Type)]
Source Number is the associated data source number.
Row corresponds to the order in which the unique failure modes appeared in the data set (i.e., row 1 = 1st unique failure mode that occurred, row 2 = 2nd unique failure mode that occurred, etc.).
Column is an index number (1 or 2) that returns the following information:
1 = returns the classification and mode.
2 = returns the time of the first failure.
Mode_Type allows you to select the mode classification. It is shown in the function as a numerical value that indicates the selected mode: A Modes = 0; BC Modes = 1; BD Modes = 2; All Modes = 3.
Remarks:
The Source Number must be either 1,2,3 or 4.
The Row and Column values must be greater than 0.
Example:
[FTTFUNIQUE(1)(1;2;2)]
Returns:
224
Note that this value will vary depending on the source data set.
© 1992-2015. ReliaSoft Corporation. ALL RIGHTS RESERVED.