Related Topics: | ||
Description: Returns the 1-sided bound at the specified confidence level on the time corresponding to the specified probability of failure.
Field Format: [BOUNDTIMEATPROB(Source Number)(Probability of Failure; Confidence Level)]
Source Number is the associated data source number.
Probability of Failure is the unreliability value in question.
Confidence Level is the percentage (entered as a decimal value) for the 1-sided confidence bounds.
Remarks:
The Source Number must be either 1, 2, 3 or 4.
The Probability of Failure and Confidence Level values must be greater than 0 and less than 1.
Example:
[BOUNDTIMEATPROB(1)(0.25;0.9)]
Returns:
77.8488
Note that this value will vary depending on the source data set.
© 1992-2015. ReliaSoft Corporation. ALL RIGHTS RESERVED.