Related Topics:

Crow Extended - Continuous Evaluation

Event Reports

Once you have calculated the parameters for the Multiple Systems with Event Codes data type or any multi-phase data type, you can choose Growth Data > Analysis > Event Report to view a special report in the Results window. The Event Report can consist of up to four tabs, depending on the types of events defined in the data set. All four tabs are described next.

Mode Summary Tab

The Mode Summary tab is always displayed and it provides the following information for each unique failure mode in the data sheet:

For the Multiple Systems with Event Codes data type, there is one additional column.

For multi-phase data types, there are three additional columns. These columns are applicable only for BD failure modes that do not have an implemented fix time (I event) in the data set. For these failure modes, the Effectiveness Factors window records the phase after which the fix will be applied, if any, along with the estimated effectiveness factor. Therefore, the report displays:

Implemented Fixes Tab

The Implemented Fixes tab is present only if the Multiple Systems with Event Codes data set contains BC failure modes, or if the multi-phase data set contains BD failure modes that have an implemented fix time (I event) in the data set. For each applicable failure mode, this tab provides the following information:

For the Multiple Systems with Event Codes data type, there is one additional column:

For multi-phase data types, if the Allow EF values for BD modes with implemented fixes option is selected on the on the Calculations page of the Application Setup, there are two additional columns:

Quality Events and Performance Events Tabs

The Quality Events tab and the Performance Events tabs are present only if the data set contains events of these types. These tabs provide summaries for the events that have been marked with the Q and P event types.

 

© 1992-2015. ReliaSoft Corporation. ALL RIGHTS RESERVED.