Related Topics: | ||
Description: Returns the conditional reliability given the specified start and additional times.
Syntax: CONDRELIABILITY_S(Data_Src, Mission Start Time, Mission Add Time)
Data_Src is the source diagram for which the conditional reliability is calculated.
Mission Start Time and Mission Add Time are the start age and additional operating time duration, respectively, of the period for which the conditional reliability is calculated.
Remarks:
The Data_Src can be one of the following values:
If using a default data source, it must be either 1, 2, 3 or 4, as selected from the Data Source Index drop-down list.
It can take a diagram name (e.g., "RBD!RBD1").
It can take a variable name defined via the Defined Names window (e.g., datasource).
The Mission Start Time and Mission Add Time values must be greater than or equal to 0.
The value returned by this function is affected by your choice in the Report folio model field on the Analysis Settings page of the diagram control panel.
Example:
CONDRELIABILITY_S("RBD!RBD1", 2000, 2500) = 0.9998
Note that this value will vary depending on the source diagram.
© 1992-2015. ReliaSoft Corporation. ALL RIGHTS RESERVED.