Related Topics:

Application Setup

Application Setup Calculations Page

The Calculations page of the Application Setup is where you set various calculation options, such as the numerical precision used in the software and whether to sort a data sheet before or after calculations.

Use this area to set the options regarding the location parameter (Gamma).

Use this check box to correct the MLE standard deviation (sigma) value for biasedness. Note that this setting applies only to the normal distribution with complete data.

The software always sorts entries based on failure times. In special cases where two or more failure times are identical to suspension times, the sort algorithm does not distinguish between them and sorts them based on the way they were entered. For example, if given a suspension time of 100 hours and a failure time of 100 hours, the results will vary depending on the order in which the data were entered and whether you are using rank regression. When the Use special sort (place F before S) option is selected and two identical times are encountered, the software will always put failures before suspensions. This involves a double sort routine and might be slightly slower than the standard sort.

Select this check box to use the plotted points (using median ranks or Kaplan-Meier) to calculate the difference between observed and model estimated probability for the Kolmogorov-Smirnov test, which is used by the Goodness of Fit Results window and the Distribution Wizard. If not selected, the non-parametric (empirical) values of the probability of failure are used as the observed value for the Kolmogorov-Smirnov test.

 

© 1992-2013. ReliaSoft Corporation. ALL RIGHTS RESERVED.